loading

Haida test equipment obtained certificate of new high-tech enterprise in 2019                                        Phone:+86-13602361535     E-mail:manager@qc-test.com

Package Clamp Test Machine HD-A534 1
Package Clamp Test Machine HD-A534 2
Package Clamp Test Machine HD-A534 3
Package Clamp Test Machine HD-A534 4
Package Clamp Test Machine HD-A534 1
Package Clamp Test Machine HD-A534 2
Package Clamp Test Machine HD-A534 3
Package Clamp Test Machine HD-A534 4

Package Clamp Test Machine HD-A534

    oops...!

    no product data.

    Go to homepage

    Specifications

    Package Clamp Test Machine 
    1.Package clamp testing machine 
    2.Up to ASTM D6055 
    3.PLC control 
     

     

    The  Parameters

     

    Clamping force

    1T

    color

    optional

    Resolution

    1/100,000

    Test Space(L x W x H)

    100x 100 x 100cm

    Test Speed

    10±3mm/min

    Weight

     around 300kg

    Power

    1#, 220V/50HZ

     

     

    Safety protection

     

    Overload protection, overvoltage protection & limited position protection device  

     

      

    Clamp Compression Testing Method of Large Products

     1.Before placing the packaged product between platens, verify that the clamp force using the clamp indicator. The indicator should be placed between the axes of the platen articulation points approximately 1/2 way up the platens.

     2.Each time the product is clamped, the force should be applied for a minimum of 15 seconds and not to exceed 1 minute.

     3. Apply the clamp force on the sample with the platens resting on the floor and the front edge of the platens flush with the front of the package (see flush platen photo 4). If the package is too large for the clamps to be flush to front edge (i.e., large refrigerator, tractor etc.), clamp as close to the edge as possible.

     4. Clamp the product a total of 10 times in the flush orientation.

     5. Apply the clamp force on the packaged product with the platens in a 6×6 inch(15.2x15.2cm) offset position(see fig 5 ). Both the horizontal and vertical offset dimensions are measured at the front bottom corner of the platen. If the package is too large for the clamp to be positioned 6-inches from the front edge (i.e., large refrigerator, tractor etc.), clamp as close to this position as possible.

        1)Exception number 1: for large products with an obvious, visible external skid(see fig 6), offset clamp testing is not conducted if the product does not extend beyond any part of the skid and there is some form of handling graphic or note that indicates to clamp only from the skid. If there is no graphic or not indicating this or there is some overhang beyond the skid, then the entire clamp test protocol is conducted.

        2) Exception number 2: If the product height, when placed in its normal shipping orientation, is ≤ 12 inches, the 6 x6 inch offset testing is not conducted.

     6. Clamp the product a total of 10 times with the clamp in the 6 x6 inch offset position.

     7. Repeat step 5.2.5 except with a 2 x6 inch offset clamp position. The 2 x6 inch offset is similar to the 6 x6 inch offset except the platens are oriented such that they are 2-inches from the floor and 6-inches back from the package’s front edge. If the package is too large for the clamps to be positioned 2-inches from the front edge (i.e., large refrigerator, tractor etc.), clamp as close to this position as possible.

     8. Repeat flush and offset clamping on all other sides of the product that are indicated in the handling graphics as acceptable for clamp handling.

    According to verdict standards, if there is one item failed the test, then put forward the “Test Failure Handling Sheet

     

    The equipment--   Package Clamp Test Machine   

     Package Clamp Test Machine HD-A534 5Package Clamp Test Machine HD-A534 6

     

     

    Clamp Compression Testing Method of Small Products

    Before clamp testing, verify that the clamp for using the clamp force indicator. The indicator should be placed between the axes of the platen articulation points approximately 1/2 way up the platens.

     During clamp compression testing of small products, 4 samples will be utilized as outlined below.

     1. If, when oriented for clamp testing (based on the handling graphics) the sides perpendicular to the platens of a single sample ≤ 24” (61cm), then the 4 sample should be placed in a”side by side”oritentation as shown to the fig 1(with 2 samples on the bottom and 2 on the top)

     2.  If, when oriented for clamp testing the sides perpendicular to the platens of a single sample are >24” (61cm),, then the 4 samples should be placed in a top-bottom orientation as shown fig 2. If, when placed 4-high, any of the samples are completely above the top of the platens, that sample can be removed from clamping in this orientation only(fig 3 shows 3 MHC’s ready for clamp testing with the 4th sample removed from testing in this orientation)

     3 Each time the samples are clamped, the force should be applied for a minimum of 15 seconds and not to exceed 1 minute.

     4 .Apply the clamp force on the samples with the platens resting on the floor and the samples flush with the front edge of the platens (see fig2). If the samples are too large for the clamps to be flush to front edge, clamp as close to the edge as possible.

     5.Clamp the product a total of 10times with the clamps in the flush orientation.

     6. Apply the clamp force on the packaged product with the platens in a 2×2 inch offset position(see fig 3). Both the horizontal and vertical offset dimensions are measured at the front bottom corner of the platen. If the package is too large for the clamps to be positioned 2-inches from the front edge, clamp as close to this position as possible.

     7. Clamp the product a total of 10 times with the clamps in the offset position.

     8. Repeat the flush and 2x2 inch offset camping on all other sides of the product that are identified in the handling graphics as acceptable for clamp handling. Please note, depending on the box geometry, you may use both the side-by-side and top-bottom orientation during clamp testing.

     

     

    The introduction of Haida

     

    Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.

     

    Package Clamp Test Machine HD-A534 7

     

    Package Clamp Test Machine HD-A534 8

     

     

    Leave A Message

    You can also contact me via email. My email address is manager@qc-test.com
    Related Products
    no data

    

    CONTACT PERSON :Mrs. Zhong
    TEL : +86-0769-8905 5588

    E-MAIL : manager@qc-test.com
    PHONE : +86-13602361535
    FACTORY ADD: No.13 Daxin Street, Daluosha Industrial Zone, Daojiao Town, Dongguan City, Guangdong Province.

    HAIDA Test Equipment

    ISTA Series Test Equipment
    Battery Test Equipment
    Environmental Test Chamber
    Tensile Test Equipment
    Paper Packaging Test Equipment
    Furniture Test Equipment
    Vibration Shaker Table Systems
    Textile Test Equipment
    Mask Making Machine
    Leather & Shoes Test Machine
    Luggage Test Equipment
    Optical Test Equipment
    Rubber and Plastic Test Equipment
    RoHS Testing Equipment
    Cookware Testing Equipment
    Car parts testing equipment

    Contact us

    Copyright © 2025 Haida International Equipment Co., Ltd. | Sitemap
    Customer service
    detect