Haida test equipment obtained certificate of new high-tech enterprise in 2019 Phone:+86-13602361535 E-mail:manager@qc-test.com
High low temperature test chamber for car seat belt can do high temperature testing , low temperature testing , rapid exchange of high and low temperature testing for car seat belt and other materials.
High temperature testing chamber range ~+175℃,and in the high temperature test, the test temperature can be raised ~+175℃ in just a few minutes,in the low temperature test, the test temperature ~ -50 ℃ only a few minutes.and the key point is that the high and low temperature range can be customized.
Usage:
High low temperature test chambe is application to automotive seat belt metal, plastic, rubber, electronic etc materials and can be used for product improvement’s reference.
Standard:
MTL, IEC, JIS, GJB etc
Main parameters:
Item |
Specification |
Test method |
Pneumatic operated door switch, two chambers |
Basket internal dimension |
320Wx230Dx250Hmm (20L) |
External chamber dimension |
1050Wx1825Dx1440Hmm |
High temperature range |
Room temperature ~+175℃ |
Low temperature range |
Room temperature ~-50℃ |
Testing time |
Maximum 1000 cycles, 30 minutes for each one |
Defrost |
Do defrost in every 20 cycles |
Temperature deviation |
3~5℃ |
Lifting switch time |
≤10 seconds |
Test hole for cable routing |
Diameter 50mm on the left of chamber attach a silicone plug |
External chamber material |
High quality electrolytic steel plate spray with powder, antirust |
Internal material |
SUS#304 stainless steel |
Thermal insulation material |
High quality superfine glass fiber |
Refrigerant |
R404A / R23 |
Cooling method |
Water cooling |
Power supply |
Three phase, 380V, 50Hz |
Operation interface: 6” Windows-based color touch screen with English version
Program’s memory capacity: 100 group user program (adjustable)
Set index range: Time: 1min~ 99h59min, cycling: 1~999times
resolution ratio: Temperature: 0.01 ℃, time 1 min
Input: T type thermocouple
Controlling method: PID control
Safety device:
ground fault circuit interrupters, the chambers temperature is too high, lower protector, air evacuation valve, Sample power control terminals (contact capacity: AC 250V, 6Am), over-temperature protector switch for hot & cold chamber, over-temperature protector switch for hot & cold chamber( inside controller), compressor overpressure, over-heating protector, ventilator relay, temperature switch of electromotor, prevent relay of electromotor, pressure switch for air compressor, fuse, external alarming terminals (contact capacity: AC 250V, 2Am)