    Walk in Battery Altitude Chamber



    APPLICATION


    Walk in battery altitude chamber is used to simulate test environments at different altitude, nd can be customized according to test requirements. This is especially important for defense and aerospace applications where pressure and vacuum conditions are worse,

    such as aviation, aerospace, communications, electronics and electrical applicances. The test objective is to ensure the maximum possible quality and reliablity of the product or material at different heights.



    STANDARD SPECIFICATIONS


    Vacuum pressure

    1 ~ 100Kpa

    Vacuum control

    Touch Screen Controller

    Vacuum unit switch

    Kpa/Mpa

    Temperature range

    RT ~ 0

    Pumping rate

    Rise rate 305m per 30-60s until setting pressure is achieved.

    Pressure holding time

    0~999h/m/s

    Inner size

    400X500X500mm (100L)

    Internal material

    SUS# 304 Stainless Steel

    External material

    Steel plate with paint coating

    Power

    Single phase, 220V/50HZ

    Test condition

    ASTM D4169 Schedule I, ASTM D6653

     

     

    ASTM D6653 TEST PROCEDURE

     

    Step 1: Select your vacuum chamber which capable of appropriately withstanding 1 atm pressure differential across the walls. The vacuum gauge must be sealed to the chamber and capable of a vacuum range from 0 to 100 kPa.

    Step 2: Determine your sampling method which should be representative of your sample to permit adequate determination of performance. If you cannot determine a good sample size, at least 3 representative samples must be selected for performance evaluation.

    Step 3: Test specimen must be conditioned to 5.6 +/- 2 Degrees Celsius for 24 hours prior to testing. Test specimens must also be tested at 5.6 +/- 2 Degrees Celsius.

    Step 4: Place the Test Specimen into the Vacuum Chamber and turn the vacuum source by making the vacuum rise by 1000 ft or 305 m for every 30 to 60 seconds until the appropriate pressure/vacuum is achieved.

    Step 5: Attain a pressure equivalent of 4,877 m +/- 5%; this correspond to an absolute pressure of 56.3 kPa, or 16.22 in Hg. An elevation of 4,267m may be aimed for if 4,877 m is not achievable or inappropriate; this corresponds to an absolute pressure of 59.5 kPa.

    Step 6: Maintain the achieved vacuum for 60 minutes.

    Step 7: After the 60 min vacuum hold time has elapsed, release the vacuum at a rate of 1000 ft or 305 m for every 30 ~ 60 seconds.

    Step 8: Once vacuum has been released, open the chamber, and examine your specimen for damage or deformation.



    Leave A Message

    You can also contact me via email. My email address is manager@qc-test.com
    Related Products
    no data

    

    CONTACT PERSON :Mrs. Zhong
    TEL : +86-0769-8905 5588

    E-MAIL : manager@qc-test.com
    PHONE : +86-13602361535
    FACTORY ADD: No.13 Daxin Street, Daluosha Industrial Zone, Daojiao Town, Dongguan City, Guangdong Province.

    Contact us

    Copyright © 2024 Haida International Equipment Co., Ltd. | Sitemap
    Customer service
    detect