    Description: RoHS 2.0 Directive 

    On June 4, 2015, the European Union issued a directive (EU) in its official gazette 2015/863 to amend RoHS2.0 (2011/65 / EU) Appendix II, and officially revised the four phthalates (DEHP, BBP, DBP, DIBP) are listed in Appendix II of RoHS2.0. As of December 31, 2016, EU member states must translate this directive into national regulations and implement them. The limits of the four new phthalates are all 0.1% (1000 ppm). The difference from the four priority evaluation substances proposed earlier is the deletion of hexabromocyclododecane (HBCDD) and the addition of DIBP as Regulated substances.

     

    In addition to meeting the Ortho-benzene detection requirements of RoHS2.0, it can also expand TOTM (trioctyl trimellitate), DMF (dimethylformamide), benzene series (benzene, toluene, xylene), and 17 kinds of inks VOCs, organic solvent residues, polymer materials, volatile organic compounds in materials and other testing items, with powerful functions in one machine.

     

    Testing principle

    The thermal cracking method is to place the solid sample in a thermal cracking device, which is heated to 350 degrees in a nitrogen-filled environment, then the phthalate ester will undergo a physical reaction, changing from a solid state to a gas state, and then, We calculated the content of gaseous phthalates by means of a gas chromatograph.

    Advantage:

    The HD-G862 ROHS 2.0 Directive solution has the following advantages:

    1> Short sample preparation time:

    20 minutes/sample preparation time fully meets the needs of enterprise users for rapid screening;

     

    2> Does not produce waste gas waste liquid:
       This does not require reagents, no pre-treatment, no waste gas waste liquid;

     

    3> Direct injection, no pre-treatment:

    Direct solid or liquid injection, no pre-treatment;

    4> Built-in standard curve:

    More intuitive to determine whether the material is too high in the benzene (exclusive technology);

     

    5> No need for a professional laboratory environment:

    Only need ordinary operating space with air conditioning power supply can be installed and used.

     

    Application

    > Large Household Appliances (such as : Air conditioner, TV, Refrigerator, etc.)

    > Small Household Appliances (Such as : Kettles, Sweeping Robots, Electric Fans, etc.)

    > IT & Communication Products (Such as: Computers, 4/5G Base Stations, Antennas, Communication Equipment, etc.);

    > Consumer Electronic & Electrical Products (Sush as: Game Consoles, Mobile Phones, Cameras, Consumer Drones, etc.);

    > Lighting Products (Such as: Civil Lamps, Street Lamps, Car Lamps, etc.);

    > Electronic & Electrical Tools (Such as: Power Tools, Motors, Servo Motors, etc.);

    > Toys, Leisure & Sports Products (Such as: Children's Toys, Bicycles, Children's Walkers, etc.);

    > Vending Machines, Medical Equipment, etc.;


    Technical Parameters

    Sample Testing Speed

    18-20 minuts per sample

    Consumables Parts

    Cracking Tube & Nitrogen

    Sample

    Avaible for both Solid and Liquid sample

    Min.Testing Content

    50ppm

    Sample Pre-treatment

    No Need

    Environmental Problem

    Environmental friendly, does not produce waste water

    Temperature Range:

    RT450

    Heating Rage:

     >500/min

    Cracking Time

    0.0199.99min

    Purge Time

    0.0199.99min

    Purge Flow Range:

    10ml200ml

    Shunt Flow Range:

    10ml200ml

    Heating Voltage

    16VDC

    Aging Cleaning Device Temp. Range

    RT450

    Aging Cleaning Device Time. Range

    11200 min


    Testing Graph:

    image.png

    Component name and retention time:

    Name

    Abbreviation

    Retention time

    Time window

    Diisobutyl Phthalate

    DIBP

    8.524

    0.05

    Dibutyl Phthalate

    DBP

    9.041

    0.05

    Butyl Benzyl Phthalate

    BBP

    10.941

    0.05

    Dioctyl Phthalate

    DEHP

    11.949

    0.05



    Leave A Message

    You can also contact me via email. My email address is manager@qc-test.com
    Related Products
    no data

    

    CONTACT PERSON :Mrs. Zhong
    TEL : +86-0769-8905 5588

    E-MAIL : manager@qc-test.com
    PHONE : +86-13602361535
    FACTORY ADD: No.13 Daxin Street, Daluosha Industrial Zone, Daojiao Town, Dongguan City, Guangdong Province.

    HAIDA Test Equipment

    ISTA Series Test Equipment
    Battery Test Equipment
    Environmental Test Chamber
    Tensile Test Equipment
    Paper Packaging Test Equipment
    Furniture Test Equipment
    Vibration Shaker Table Systems
    Textile Test Equipment
    Mask Making Machine
    Leather & Shoes Test Machine
    Luggage Test Equipment
    Optical Test Equipment
    Rubber and Plastic Test Equipment
    RoHS Testing Equipment
    Cookware Testing Equipment
    Car parts testing equipment

    Contact us

    Copyright © 2024 Haida International Equipment Co., Ltd. | Sitemap
    Customer service
    detect