    Usage

    Tape Initial Adhesion Tester is suitable for testing sensitive adhesive tapeand the product similar to the pressure sensitive adhesive tape products.

    Definition:Initial adhesion——Objects and pressure-sensitive adhesive tape with small pressure brief contact between the cohesive surface, the adhesion of adhesive tape that effect onobjects called initial adhesion.

    Principle

    Inclinedplanet roll ball device: Through steel and pressure-sensitive adhesive tape with small pressure brief touchingbetween the cohesive surface, the adhesion of adhesive tape that effect onsteelto test initial adhesion.

     

     

    Standard

    Reference standard:GB/T4852

     

    Equipment Instruction

    Test Equipment:                                                                                                     

    Inclinedplaneroll ball device(Picture1)

    This device is mainly composed of inclined plate,the device that put the ball, support, base, catching box partsetc. As shown in Picture 1

    Tape Initial Adhesion Tester 4

    1 . Release ball device  2. Inclined board    3. Catching ball box  4. Support   5.Dial   6.Based     7.Bubble            8. Angle pointer        9. Button corner adjustment                

     

    Instruction

    • Inclined board:Covered the 7mm steel plate with 2mm thick glass plate, and form inclined plate. Lining mm coordinate paper, to place the sample, adjust the mark of start and end.
    • Pull the ball machine:Put ball machine should be able to adjust the starting position of steel ball oninclined plate, the ball should be without any additional forcewhen release the steel ball,

    3、Support:The support be used for support the inclined plate, and could adjust the angle of plate in the range of 0~60°.

    4、Base:The base should be able to adjust and maintain the device in the level.

     

    5、Catching ball box:Catching ball box be used toreceiving rolling steel ballon the plate, inside with the soft material.

    Steel ball

       Made of GCr15 bearing steel the accuracy of it is not lower than “0” level of regulation of GB 308-77 steel ball, it is the 33 kind steel ball which diameter is 1 inch, could be used as test steel ball.

    The steel ball is name the ball number according to the 32 times according to the inch diameter. Should use a set of steel ball that it is continuous number

    Steel ball should be stored in anti-rust oil. The rust and scars ball should change in time.

    Cleaner and wipe the material

    3.1Eliminate lotion: lotion can be used appropriate solventsuch as chemical pure acetone, ethyl acetate, ethanol etc.

    3.2Wipe the material:Use the soft fabrics such as absorbent gauze wipe as materials. This kind of material shall not contain substances soluble in the solvent.

     

    Specification

     

     

    Item

    Specification

    Angle of Inclination

    0-45°(Adjustable)

    Roll ball

    Steel ball

    The size of roll ball

    1/32”-1”

    Inclined board

    Thickness 5m glass

    Runway

    Length 100mm

    Weight(about)

    About 3kg

     

     

    Our company

    Introduction:

    HAIDA INTERNATIONAL is a professional manufacturer of various kinds of testing equipments over 24 years. HAIDA products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and applicable to all scientific research units, quality inspection institutions and academic fields.

     Tape Initial Adhesion Tester 5 

     

    After-service

    If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation manual. We can provide video-conference. If customers require on-site service, the transport and travel expense shall be borne by customer;

     

     

    Leave A Message

    You can also contact me via email. My email address is manager@qc-test.com
    Related Products
    no data

    

    CONTACT PERSON :Mrs. Zhong
    TEL : +86-0769-8905 5588

    E-MAIL : manager@qc-test.com
    PHONE : +86-13602361535
    FACTORY ADD: No.13 Daxin Street, Daluosha Industrial Zone, Daojiao Town, Dongguan City, Guangdong Province.

    Contact us

    Copyright © 2024 Haida International Equipment Co., Ltd. | Sitemap
    Customer service
    detect