loading

Haida test equipment obtained certificate of new high-tech enterprise in 2019                                        Phone:+86-13602361535     E-mail:manager@qc-test.com

HD-E808-60 Corrosion Resistance Tester 1
HD-E808-60 Corrosion Resistance Tester 2
HD-E808-60 Corrosion Resistance Tester 3
HD-E808-60 Corrosion Resistance Tester 1
HD-E808-60 Corrosion Resistance Tester 2
HD-E808-60 Corrosion Resistance Tester 3

HD-E808-60 Corrosion Resistance Tester

    oops...!

    no product data.

    Go to homepage


    Corrosion Resistance Tester


    HD-E808-60 Corrosion Resistance Tester 4
    Applications:

    Corrosion Resistance Tester adapted to the surface treatment of various materials, including paint, electroplating, organic and inorganic coating, anode processing, antirust oil and so on, after these anti-corrosive treatment to test the corrosion resistance of their products.suitable for parts, electronic components, metal materials, protective coatings and industrial products.


    HD-E808-60 Corrosion Resistance Tester 5                

    Hardware

    HD-E808-60 Corrosion Resistance Tester 6                

    Electrical Appliances

    HD-E808-60 Corrosion Resistance Tester 7                

    Automotive

    HD-E808-60 Corrosion Resistance Tester 8                

    Electronics


    Experiment method:

    ASTM B117-08, ISO 9227 

    And IEC, MIL, DIN, ASTM and other standards equivalent to





    Feature:

    1, Durable hard 8 mm PVC construction, anti-corrosion and easy to clean.

    2, Reservoirs with mixing system on stand.

    3, Separate heating system apart from salt testing chamber to ensure accurate result and protect circuit.

    4, Exposure zone lined with corrosion-resistant PVC sheets.

    5, Clear cover allows viewing of test conditions.

    6, Peaked cover prevents dripping of condensation onto samples.

    7, Water seal and water level protection system.

    8, Heated humidifying tower with air relief valve, adjustable tower tip to orient salt fog.

    9, Automatic DI water fills to humidifying tower.

    10, Digital temperature control.

    11, Integral over-protection on heaters.

    12, Low water cut-off protection on humidifying tower.


    Method of operation:

    1, the salt spray chamber internal parts: tower spray device, funnel, rod, V-type sample holder installed.

    2, connected to the gas supply, the power is turned on, turn on the power switch.

    3, in the pressure tank and cabinets add water, two low level light exterminate stop adding water, at the water seal groove seal.

    4, purified water and sodium chloride salt in a ratio of 1:20 with a good. The solution was poured into the reagent with a good entrance (low saline to exterminate a lamp).

    5, we can open all the lamps burn out operation, spray, time switch, switch demisting before opening end of the test.

    6, according to the test requirements for equipment and cycles for continuous spraying mode (continuous spray T1, T2 tables are all set to 0, T1 is set to intermittent spray working time, T2 is time to rest).



    Specifications:

    Model

    HD-E808-60

    Internal Size (W*D*H)

    600*450*400mm

    External Size (W*D*H)

    1060*580*1050mm

    Chamber material

    P.V.C rigid plastic plate, thickness 8mm

    Sample tray

    Diameter 10mm glass fiber rod, anti-rust

    V-shape plastic steel to make sure sample in 15~30 degree inclined

    Temperature Range

    Room temperature ~ 55℃

    Temperature Fluctuations

    ≤±0.5℃

    Temperature Uniformity

    ≤±2℃

    Temperature Precision

    ±1℃

    Spraying method

    Continuous and Periodic spray type

    Test Chamber Temperature

    Salt Spray Method (NSS ACSS)35±1℃
    Corrosion-resistant Testing Method (CASS) 50±1℃

    Saturated air Barrel Temperature

    Salt Spray Method (NSS ACSS)47±1℃
    Corrosion-resistant Testing Method (CASS) 63±1℃

    Brine Temperature

    35℃±1℃

    Spray Quantity

    1.0~2.0 ml / 80cm2 / hr

    PH value

    Salt Spray Method (NSS ACSS6.5~7.2)
    Corrosion-resistant Testing Method(CASS)3.0~3.2

    Lab Volume

    108L

    Brine Tank Capacity

    25L

    Multiple Safety Protection Devices

    Current discharge protection, over pressure protection, over temperature protection, over load fuse protection

    Accessories

    Testing Salt/ Measuring tank/Nozzle Equipment x 1 set

    Air source

    1HP Air pump (provided by buyer)



                  Structure



    HD-E808-60 Corrosion Resistance Tester 9                
    Presssure Regulating Valve

    The pressure regulating valve is used for adjusting the pressure inside the chamber when the air pressure is over high or low

    HD-E808-60 Corrosion Resistance Tester 10                
    Pressure Gage

    The pressure gage can display the pressure value when the heated air reaches the nozzle by going throug the Saturated air tank.

    HD-E808-60 Corrosion Resistance Tester 11                
    Measuring Pail

    Gather the volume of spray of each test 50ml per degree


    Leave A Message

    You can also contact me via email. My email address is manager@qc-test.com
    Related Products
    no data

    

    CONTACT PERSON :Mrs. Zhong
    TEL : +86-0769-8905 5588

    E-MAIL : manager@qc-test.com
    PHONE : +86-13602361535
    FACTORY ADD: No.13 Daxin Street, Daluosha Industrial Zone, Daojiao Town, Dongguan City, Guangdong Province.

    Contact us

    Copyright © 2024 Haida International Equipment Co., Ltd. | Sitemap
    Customer service
    detect